Ecophon Focus™ A

For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600

1200
X
1200
XL
1600
X
600
XL
1800
X
600
XL
2000
X
600
XL
2400
X
600
T24
T15        
Thickness 20 20 20 20 20 20 20
Inst. diagr. m01 m01 m01 m46
m16
m46
m16
m46
m16
m46
m16

The systems consist of Ecophon Focus A tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are primed. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,c,w=20 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=21 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=190 according to ASTM E 1111 and E 1110.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency Hz
Ecophon Focus A 200 mm o.d.s.
--- Ecophon Focus A 50 mm o.d.s.
o.d.s = overall depth of system

Product Focus A
O.d.s. mm 400 200 80 50
Absorption class   A A B
NRC 0.85     0.85
SAA 0.88     0.83

Focus A tile
Section of Focus A system with Connect T24
Focus A system
ACCESSIBILITY: The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection). Colours: See Ecophon colour range.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m01, 1200x1200 50 160
m01, 1200x600 50 160
m01, 600x600 50 160
m16, 2400x600 0 -
m16, 2000x600 10 -
m16, 1800x600 20 -
m16, 1600x600 40 -
m46, 1600x600 50 160
m46, 1800x600 50 160
m46, 2000x600 50 160
m46, 2400x600 50 160
INSTALLATION: Installed according to installation diagrams M01, M16 or M46, which include information regarding minimum overall depth of system.
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M01) for Focus A
Size, mm
600x600 1200x600 1200x1200
Focus A 2.8/m² 1.4/m² 0.7/m²
1 Connect T24 or T15 Main runner, installed at 1200 mm centres 0.9 m/m² 0.9 m/m² 0.9 m/m²
2 Connect T24 or T15 Cross tee, L=1200 mm 1.7 m/m² 1.7 m/m² 0.9 m/m²
3 Connect T24 or T15 Cross tee, L=600 mm 0.9 m/m² - -
4 Connect Adjustable hanger, installed at 1200 mm centres (max distance from wall 600 mm) 0.7/m² 0.7/m² 0.7/m²
5 Connect Hanger clip 0.7/m² 0.7/m² 0.7/m²
6 For direct installation: Connect Direct bracket, installed at 1200 mm centres 0.7/m² 0.7/m² 0.7/m²
7 Connect Angle trim, fixed at 300 mm centres as required as required as required
8 Connect Shadow-line trim, fixed at 300 mm centres as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M16) for Focus A XL in corridors
Size, mm
1600x600 2000x600 2400x600 1800x600
Focus A 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Corridor profile, installed at 600 mm centres 1.05/m² 0.85/m² 0.7/m² 0.95/m²
2 Connect Angle trim, fixed at 200 mm centres as required as required as required as required
3 Connect Shadow-line trim, fixed at 200 mm centres as required as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M46) for Focus A XL
Size, mm
1600x600 2000x600 2400x600 1800x600
Focus A 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Main runner, installed at 600 mm centres 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m²
2 Connect T24 Cross tee, L=600 mm 0.65 m/m² 0.5 m/m² 0.45 m/m² 0.6 m/m²
3 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm) 1.1/m² 1.1/m² 1.1/m² 1.1/m²
4 Connect Hanger clip 1.1/m² 1.1/m² 1.1/m² 1.1/m²
5 Connect Angle trim, fixed at 300 mm centres as required as required as required as required
6 Connect Shadow-line trim, fixed at 300 mm centres as required as required as required as required