Ecophon Focus™ C

For applications where a suspended ceiling with a concealed grid is required and demountability is not needed. Ecophon Focus C is installed in a suspended grid system or directly to the soffit, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600
Concealed grid
Glue  
Screw
Thickness 20 20
Inst. diagr. m03
m96
m109
m04
m96
m109
m04

The systems consist of Ecophon Focus C tiles and Ecophon Connect grid systems, with an approximate weight of 3,5 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
The table below shows the sound absorption classification according to EN ISO 11654, but includes also the single value ratings NRC and SAA measured and calculated according to ASTM C 423.
SOUND INSULATION: Dn,c,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1.CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=180 according to ASTM E 1111 and E 1110.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Focus C 200 mm o.d.s.
--- Ecophon Focus C 35 mm o.d.s.
o.d.s = overall depth of system

Product Focus C
O.d.s. mm 400 200 75 50 35
Absorption class   A A B C
NRC 0.8     0.85 0.85
SAA 0.82     0.85 0.83

Focus C tile
Section of Focus C system
Focus C system
Focus C with Connect Channel trim
ACCESSIBILITY: The tiles are not demountable. If necessary, inspection panels can be installed to allow for servicing the installations in the ceiling void.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection). Colours: See Ecophon colour range.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m03, 600x600 -
m04, 1200x600 50 160
m04, 600x600 50 160
m109, 1200x600 50 160
m109, 600x600 50 160
m96, 1200x600 -
m96, 600x600 -
INSTALLATION: Installed according to installation diagram M03 (see Focus B), M04 or M109, which include information regarding minimum overall depth of system. Installation with glue according to M03 requires smooth, clean and dry sub-surfaces of concrete, lightweight concrete, plaster or wood fibre. It is advisable to carry out adhesion tests on painted or suspect surfaces.
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M03) Focus B or C, using A-cement
Size, mm
600x600
Focus C 2.8/m²
1 Focus B or C. Focus C: Visible edges should be painted 2.8/m²
2 Connect A-cement 0044, diameter 40 mm 0.9 l/m²
3 Focus C: Connect Splines 0219, L=150 mm 2.8/m²
4 For installation of floating ceilings: Connect Wood trim 2561, L=2500 as required
Quantity specification (excl. wastage)
Installation diagram (M04) for Focus C, suspended installation
Size, mm
600x600 1200x600
Focus C 2.8/m² 1.4/m²
1 Connect T24 Main runner 8101, installed at 1200 mm centres 0.9 m/m² 0.9 m/m²
2 Connect Wire clip 0024 1.4/m² 1.4/m²
3 Connect Z-profile 0227, installed at 600 mm centres 1.7 m/m² 1.7 m/m²
4 Connect Splice Connector Z 0501 0.4/m² 0.4/m²
5 Connect Spline 0219, L=150 2.8/m² 1.4/m²
6 Connect T-spline 0011, L=600 2.8/m² 1.4/m²
7 Connect Adjustable hanger, installed at 1200 mm centres (max distance from wall 600 mm) 0.7/m² 0.7/m²
8 Connect Angle trim, fixed at 300 mm centres as required as required
9 Connect Shadow-line trim, fixed at 300 mm centres as required as required
11 Connect Inspection 0480
Quantity specification (excl. wastage)
Installation diagram (M109) for Focus C, direct installation
Size, mm
600x600 1200x600
Focus C 2.8/m² 1.4/m²
1 Connect Z-profile 0227, installed at 600 mm centres 1.7 m/m² 1.7 m/m²
2 Connect Direct fixing plate 0214 (installed at 1200 mm centres) 1.4/m² 1.4/m²
3 Connect Splice Connector Z 0501 0.4/m² 0.4/m²
4 Connect Spline 0219, L=150 mm 2.8/m² 1.4/m²
5 Connect T-spline 0011, L=600 mm. To comply with fire class "Tändskyddande beklädnad" 2.8/m² 1.4/m²
6 Connect Angle trim, fixed at 300 mm centres as required as required
7 Connect Shadow-line trim, fixed at 300 mm centres as required as required
8 For installation of floating ceilings: Connect Channel trim 0623 as required as required
9 Accessory for Sweden, Denmark, Norway and Finland. Connect Fire rated plate 0725 placed here at fireclass "Tändskyddande beklädnad". 1.4/m² 1.4/m²
Quantity specification (excl. wastage)
Installation diagram (M96) for Focus C
Size, mm
600x600 1200x600
Focus C 2.8/m² 1.4/m²
1 Connect Direct fixing plate 0299 2.8/m² 1.4/m²
2 Connect Spline 0219, L=150 2.8/m² 1.4/m²
3 Connect Angle trim, fixed at 300 mm centres as required as required

Sponsors of this page: Fito spray related to http://fitospray.eu.