Ecophon Focus™ F

For applications requiring a ceiling which is mechanically secured to the structural soffit. Ecophon Focus F is installed directly to an existing plaster ceiling, boarding, battens or concrete, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600
Screw
Thickness 20 20
Inst. diagr. m15 m15

The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are reinforced and painted. The weight is approximately 2,5 kg/m².

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
···· Ecophon Focus F 20 mm o.d.s.
--- Ecophon Focus F 40 mm o.d.s.
Ecophon Focus F 430 mm o.d.s. including 385 mm thermal insulation.
o.d.s = overall depth of system

Product Focus F
O.d.s. mm 20 40 430
Absorption class C C A
NRC 0.75    
SAA 0.77    

Focus F tile
Section of Focus F system
Focus F system
Focus F is installed by screw fixing
ACCESSIBILITY: The tiles are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: Additional live load has to be secured to the soffit.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m15, 1200x600 -
m15, 600x600 -
INSTALLATION: Installed according to installation diagram M15, which includes information regarding minimum overall depth of system. For larger areas (>50m2) it can be more cost efficient to make the direct fixed installation with Focus C and Z-profiles according to M109. Displaced joints (brick pattern) will facilitate the alignment of the joints.
Installation Guides (pdf)
Size, mm
600
X
600

1200
X
600
Installation Guide IG 1008
IG 1006
IG 1008
IG 1006
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M15) for Focus F
Size, mm
600x600 1200x600
Focus F 2.8/m² 1.4/m²
1 Connect Direct fixing plate F 0149, installed at 600 mm centres (for use in concrete) 2.8/m² 2.8/m²
2 Connect Anchor screw 4000, installed at 600 mm centres (for use in concrete) 2.8/m² 2.8/m²
3 Connect Installation screw F 4003, installed at 200 mm centres (for use in plasterboard or timber) 8.3/m² 7/m²
4 Connect Spline F 0160, L=600 mm. Must be used in Sweden, Denmark, Norway and Finland at fireclass "Tändskyddande beklädnad" 2.8/m² 1.4/m²
5 Connect Spline 0219, L=150 mm 2.8/m² 1.4/m²
6 Connect Wall spring spacer 0087 1 per panel in the last row 1 per panel in the last row
7 Connect Angle trim, fixed at 300 mm centres as required as required
8 For use when installing floating ceilings: Connect Wood trim 2561, L=2500 mm, fixed at 500 mm centres as required as required