Ecophon Focus™ Flexiform

The Ecophon Focus Flexiform panel is delivered flat and formed on site into concave or convex form (min. radius 200 mm and max. radius 10 m) by means of special profiles. It is ideal for creating surfaces with special curvatures, or if the dimensions of the installations etc. above the suspended ceiling cannot be accommodated by using preformed ceiling elements. The panels are not demountable.
SYSTEM RANGE
Size, mm
1200
X
600

1600
X
600

2000
X
600

2400
X
600
T24
Thickness 30 30 30 30
Inst. diagr. m31ic
m31
m31ec
m31ic
m31
m31ec
m31ic
m31
m31ec
m31ic
m31
m31ec

The system consists of Ecophon Focus Flexiform panels and Ecophon Connect grid systems. The weight is approximately 3 kg/m², depending on the installation method. The panels have a special glass wool core which allow the product to be formed to the required shape. The visible surface has an Akutex T coating. The edges are natural. The grid is manufactured from aluminium.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Focus Flexiform 200 mm o.d.s.
o.d.s = overall depth of system

Product Focus Flexiform
O.d.s. mm 400 200
Absorption class   B
NRC 0.9  
SAA 0.91  

Focus Flexiform panel
Section of Focus Flexiform system with Connect T24
Focus Flexiform system
Detail of Focus Flexiform
CORNER ARRANGEMENTS: Internal and external corners are cut on site during installation. Special corner profiles are available.
ACCESSIBILITY: The panels are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The panels withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
ENVIRONMENTAL INFLUENCE: Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 B-s1,d0
The glass wool core of the panels is tested and classified as non-combustible according to prEN ISO 1182. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: Additional live load has to be secured to the soffit.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m31, 1200x600 -
m31, 1600x600 -
m31, 2000x600 -
m31, 2400x600 -
m31ec, 1200x600 -
m31ec, 1600x600 -
m31ec, 2000x600 -
m31ec, 2400x600 -
m31ic, 1200x600 -
m31ic, 1600x600 -
m31ic, 2000x600 -
m31ic, 2400x600 -
INSTALLATION: Installed according to installation diagram M31. (Please note: Extreme incident light, near windows or other light sources, can create undesired shadow effects on the structured surface on curved installations.)
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M31) for Flexiform
Size, mm
1200x600 1600x600 2000x600 2400x600
Focus Flexiform as required as required as required as required
1 Connect T24 Cross tee as required as required as required as required
2 Connect Adjustable hanger, installed at 1200 mm centres as required as required as required as required
3 Connect Clip 100/20 0249 as required as required as required as required
4 Connect Hanger clip as required as required as required as required
5 Connect T24 Main runner as required as required as required as required
6 Connect T24 Cross tee as required as required as required as required
7 Connect Flexiform profile/Flexible Flexiform profile 0340, installed at 600 mm centres. Radius of curve (concave or convex) min 200 mm. Length of profile: max 2400 mm. When Flexiform profiles are longer than 1 m, intermidiate suspension are required. as required as required as required as required
8 Connect Flexiform clip 0013, fixed at 100-300 mm depending on the radius of curve as required as required as required as required
9 Connect T24 Main runner as required as required as required as required
Quantity specification (excl. wastage)
External corner (M31EC) for Flexiform
Size, mm
1200x600 1600x600 2000x600 2400x600
Focus Flexiform as required as required as required as required
1 Connect Flexiform profile, installed at 600 mm centres as required as required as required as required
2 Connect Adjustable hanger, installed at 1200 mm centres as required as required as required as required
3 Connect Hanger clip as required as required as required as required
4 Connect T24 Cross tee as required as required as required as required
5 Connect T24 Main runner as required as required as required as required
6 Connect Clip 100/20 0249 as required as required as required as required
7 Connect T24 Main runner as required as required as required as required
8 Connect Flexible external corner profile 0500 as required as required as required as required
9 Connect Flexiform clip 0013 as required as required as required as required
10 Connect F-trim 0889 as required as required as required as required
11 Connect T24 Cross tee as required as required as required as required
Quantity specification (excl. wastage)
Internal corner (M31IC) for Flexiform
Size, mm
1200x600 1600x600 2000x600 2400x600
Focus Flexiform as required as required as required as required
1 Connect T24 Cross tee as required as required as required as required
2 Connect Flexiform profile, installed at 600 mm centres as required as required as required as required
3 Connect T24 Main runner as required as required as required as required
4 Connect Adjustable hanger, installed at 1200 mm centres as required as required as required as required
5 Connect Hanger clip as required as required as required as required
6 Connect Clip 100/20 0249 as required as required as required as required
7 Connect Flexiform clip 0013 as required as required as required as required
8 Connect Flexible Flexiform profile 0340 as required as required as required as required
9 Connect F-trim 0889 as required as required as required as required