Ecophon Master™ E

Suitable for schools, open plan offices or other premises where strict demands are made on good acoustics and speech intelligibility. Ecophon Master E has a recessed visible grid and a tegular edge design, creating a ceiling with a shadow effect that accentuates each tile and partially conceals the grid system. The visible surface of each tile is 10 mm below the grid. Each tile is easily demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
1200
T24
Thickness 40 40
Inst. diagr. m58 m58

The system consists of Ecophon Master E tiles and Ecophon Connect grid systems, with an approximate weight of 5 kg/m². The tiles are manufactured from high density glass wool. The visible surface is available with three different surface coatings to meet different sound absorption needs: alpha (Akutex T coating), beta and gamma. The back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,c,w=29 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=31 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=190 (Master E/alpha) according to ASTM E 1111 and E 1110. Master E/beta and Master E/gamma are not suitable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Master E/alpha 200 mm o.d.s.
···· Ecophon Master E/beta 200 mm o.d.s.
--- Ecophon Master E/gamma 200 mm o.d.s.
o.d.s = overall depth of system




— Ecophon Master E/alpha 60 mm o.d.s.
···· Ecophon Master E/beta 60 mm o.d.s.
--- Ecophon Master E/gamma 60 mm o.d.s.
o.d.s = overall depth of system

Product Master E Master E Master E
O.d.s. mm 400 200 60 200 60 200 60
Absorption class   A A C C E D
NRC 0.9   1   0.8   0.45
SAA 0.89   0.98   0.78   0.37

Master E tile
Section of Master E system
Master E system
Master E system with Connect zinc
ACCESSIBILITY: The tiles are easily demountable. Minimum demounting depth according to installation diagram.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The system is classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m58, 1200x1200 40 160
m58, 600x600 40 160
INSTALLATION: Installed according to installation diagram M58, which includes information regarding minimum overall depth of system.
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M58) for Master E
Size, mm
600x600 1200x1200
Master E 2.8/m² 0.7/m²
1 Connect T24 Main runner, installed at 1200 mm centres 0.9 m/m² 0.9 m/m²
2 Connect T24 Cross tee, L=1200 mm 1.7 m/m² 0.9 m/m²
3 Connect T24 Cross tee, L=600 mm 0.9 m/m² -
4 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm) 0.7/m² 0.7/m²
5 Connect Hanger clip 0.7/m² 0.7/m²
6 For direct installation: Connect Direct bracket, installed at 1200 mm centres 0.7/m² 0.7/m²
7 Connect Angle trim, fixed at 300 mm centres as required as required
8 Connect Shadow-line trim, fixed at 300 mm centres as required as required
11 Connect E-plug 0148 (for Shadow-line trim) as required as required
201 Master Extra Bass 1200x600x100 mm as required as required