Ecophon Master™ F

Suitable for schools, open plan offices or other premises where strict demands are made on good acoustics and speech intelligibility. Ecophon Master F is installed directly to an existing plaster ceiling, boarding, battens or concrete, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600
Screw
Thickness 40 40
Inst. diagr. m52 m52

The tiles are manufactured from high density glass wool. The visible surface is available with three different surface coatings to meet different sound absorption needs: alpha (Akutex T), beta and gamma. The back of the tile is covered with glass tissue. The edges are reinforced and painted. The weight is approximately 5 kg/m².

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable
SOUND PRIVACY: Not applicable

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
— Ecophon Master F/alpha 40 mm o.d.s.
···· Ecophon Master F/beta 40 mm o.d.s.
--- Ecophon Master F/gamma 40 mm o.d.s.
o.d.s = overall depth of system




— Ecophon Master F/alpha 60 mm o.d.s.
o.d.s = overall depth of system

Product Master F/alpha Master F/beta Master F/gamma
O.d.s. mm 40 60 40 40
Absorption class A A C E
NRC 0.95      
SAA 0.95      

Master F tile
Section of Master F system with tongue and grove
Master F system
Master F is installed by screw fixing
ACCESSIBILITY: The tiles are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The system is classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: Additional live load has to be secured to the soffit.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m52, 600x600 -
INSTALLATION: Installed according to installation diagram M52, which includes information regarding minimum overall depth of system. For larger areas (>50m2) it can be more cost efficient to make the direct fixed installation with Master C and Z-profiles according to M111. Displaced joints (brick pattern) will facilitate the alignment of the joints.
Installation Guides (pdf)
Size, mm
600
X
600

1200
X
600
Installation Guide IG 1008
IG 1006
IG 1008
IG 1006
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M52) for Master F
Size, mm
600x600 1200x600
Master F 2.8/m² 1.4/m²
1 Connect Direct fixing plate F 0152, installed at 600 mm centres (for use in concrete) 2.8/m² 2.8/m²
2 Connect Anchor screw 4000, installed at 600 mm centres (for use in concrete) 2.8/m² 2.8/m²
3 Connect Installation screw 4033, fixed at 200 mm centres (for use in plasterboard or timber) 8.3/m² 7/m²
4 Connect Spline F 0160, L=600 mm. Must be used in Sweden, Denmark, Norway and Finland at fireclass "Tändskyddande beklädnad" 2.8/m² 1.4/m²
5 Connect Spline 0219, L=150 mm 2.8/m² 1.4/m²
6 Connect Wall spring spacer 0087 1 per panel in the last row 2 per panel in the last row
7 Connect Angle trim, fixed at 300 mm centres as required as required
8 For use when installing floating ceilings: Connect Wood trim 2141, L=3000, fixed at 500 mm centres as required as required
9 Timber installed at 600 mm centres (300 mm if thermal insulation is placed above), with the screw fixings along the timber. - -

Sponsors of this page: Titan Gel shop