Ecophon Advantage™ E

For applications requiring a suspended ceiling which is easy to install and demount, whilst meeting essential functional requirements. Ecophon Advantage E has a recessed visible grid and a tegular edge design, creating a ceiling with a shadow effect that accentuates each tile and partially conceals the grid system. The visible surface of each tile is 7 mm below the grid. Each tile is easily demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600
T24
T15
Thickness 15 15
Inst. diagr. m122 m122

The system consists of Ecophon Advantage E tiles and Ecophon Connect grid systems, with an approximate weight of 2,5 kg/m². The tiles are manufactured from high density glass wool. The visible surface is a batch painted glass tissue in white and the back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Advantage E 200 mm o.d.s.
--- Ecophon Advantage E 60 mm o.d.s.
o.d.s = overall depth of system

Product Advantage E
O.d.s. mm 400 200 110 90 60
Absorption class   A A B C
NRC 0.85       0.85
SAA 0.86       0.83

Advantage E tile
Section of Advantage E system with Connect T24
Advantage E system with Connect T24
ACCESSIBILITY: The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
CLEANABILITY: Weekly dusting and vacuum cleaning.
LIGHT EFFICIENCY: White 500, nearest NCS colour sample S 0500-N, 83% light reflectance. Since Advantage E has a batch painted glass tissue surface it can look irregular if used in combination with indirect lighting.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to ISO 1182. The system is classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m122, 1200x600 50 160
m122, 600x600 50 160
INSTALLATION: Installed according to installation diagram M122, which includes information regarding minimum overall depth of system. (The tiles have to be installed according to the arrows on the back of the tile.)
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M122) for Advantage E
Size, mm
600x600 1200x600
Advantage E 2.8/m² 1.4/m²
1 Connect T24 or T15 Main runner, installed at 1200 mm centres 0.9 m/m² 0.9 m/m²
2 Connect T24 or T15 Cross tee, L=1200 mm 1.7 m/m² 1.7 m/m²
3 Connect T24 or T15 Cross tee, L=600 mm 0.9 m/m² -
4 Connect Adjustable hanger, installed at 1200 mm centres (max distance from wall 600 mm) 0.7/m² 0.7/m²
5 Connect Hanger clip 0.7/m² 0.7/m²
6 For direct installation: Connect Direct bracket, installed at 1200 mm centres 0.7/m² 0.7/m²
7 Connect Angle trim, fixed at 300 mm centres as required as required
8 Connect Shadow-line trim, fixed at 300 mm centres as required as required
12 Connect E-plug 0158/0154 (for Shadow-line trim) as required as required