Ecophon Access™ frieze

For applications where a smooth continuous transition between the ceiling and the wall is needed. The Access frieze is developed for installation together with Ecophon Access panels. The frieze is connected to the wall without any visible trims. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
SYSTEM RANGE
Size, mm
2400
X
600
Special fixing
Thickness 20
Inst. diagr. m114

The system consists of Ecophon Access frieze tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Access frieze 200 mm o.d.s.
o.d.s = overall depth of system

Product Access frieze
O.d.s. mm 400 200
Absorption class   A
NRC 0.8  
SAA 0.82  

Access frieze tile
Access frieze system
Access frieze with Connect Frieze bracket
Access frieze with Connect Frieze trim 0562
ACCESSIBILITY: The tiles are not demountable.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection).
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: The individual panel can take additional load according to the conditions in Functional demands, Mechanical properties.
INSTALLATION: Installed according to installation diagram M114, which includes information regarding minimum overall depth of system.
Installation Guides (pdf)
Size, mm
2400
X
600
Installation Guide IG 110
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M114) for Access frieze
Size, mm
2400x600
Access frieze
1 Access panel
2 Access frieze (can be divided in two parts if width is less than 300 mm)
3 Access Transition profile 0151
4 Connect Frieze bracket 0043, installed at maximum 500 mm centre. Minimum free depth above tile 150 mm.
5 Connect Frieze trim 0562, fixed at 300 mm centres. Minimum free depth above tile 0 mm
6 Connect Sealant 0046