Ecophon Focus Frost Ds™

For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Frost Ds has a concealed grid and symmetrical edge design, allowing easier assembly, integration of light fittings and ventilation. The ceiling has an even appearance, with the bevelled edges forming a discreet groove between the tiles. The tiles are easily demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600

1200
X
1200

1600
X
600

1800
X
600

2000
X
600

2400
X
600
T24
Thickness 20 20 20 20 20 20 20
Inst. diagr. m208
m206
m208
m206
m207 m208
m206
m208
m206
m208
m206
m208
m206

The systems consist of Ecophon Focus Frost Ds tiles and Ecophon Connect grid systems, with an approximate weight of 3-4 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex Frost coating and the back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel. The system is patented in the US, and patent pending in Europe.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,c,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=180 according to ASTM E 1111 and E 1110.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Focus Frost Ds 200 mm o.d.s.
--- Ecophon Focus Frost Ds 50 mm o.d.s.
o.d.s = overall depth of system

Product Focus Frost Ds
O.d.s. mm 400 200 75 60
Absorption class   A A B
NRC 8     9
SAA 82     9

Focus Frost Ds tile
Section of Focus Frost Ds system
Focus Frost Ds system
The individual tiles are easily demountable
ACCESSIBILITY: The tiles in size 600x600 and 1200x600 are easliy demountable. The tiles in size 1200x1200 and XL sizes are demountable. Minimum demounting depth according to installation diagrams.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 500, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Colours: See Ecophon colour range.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
INSTALLATION: Installed according to installation diagram M206, M207, M208 or M205, which include information regarding minimum overall depth of system. Since the tiles need precise positioning, integration of services requires extra care during design and installation in order to achieve a good end result.
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M205) for Focus Frost Ds XL in corridors
Size, mm
1600x600 2000x600 2400x600 1800x600
Focus Frost Ds 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Corridor profile, installed at 600 mm centres 1.05/m² 0.85/m² 0.7/m² 0.95/m²
2 Connect End fixing plate 0193 2.1/m² 1.7/m² 1.4/m² 1.9/m²
3 Connect Angle trim, fixed at 200 mm centres as required as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M206) for Focus Frost Ds 600x600, 1200x600 mm and Focus Frost Ds XL. Suspended installation
Size, mm
600x600 1200x600 1600x600 2000x600 2400x600 1800x600
Focus Frost Ds 2.8/m² 1.4/m² 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Main runner HD 7101, installed at 600 mm centres 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m²
2 Connect Wall bracket T-profile 0524 1 for every suspended row of Main runner 1 for every suspended row of Main runner 1 for every suspended row of Main runner 1 for every suspended row of Main runner 1 for every suspended row of Main runner 1 for every suspended row of Main runner
3 Connect Space bar 0520, installed at 1500 mm centres (max. distance from wall 300 mm) 0.7 m/m² 0.7 m/m² 0.7 m/m² 0.7 m/m² 0.7 m/m² 0.7 m/m²
4 Connect Wall bracket Space bar 0525 1 for every row of Space bar 1 for every row of Space bar 1 for every row of Space bar 1 for every row of Space bar 1 for every row of Space bar 1 for every row of Space bar
5 Connect Cross tee 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner
6 Connect Split pin 0523, installed one per joint Main runner/Space bar 1.4/m² 1.4/m² 1.4/m² 1.4/m² 1.4/m² 1.4/m²
7 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm) 0.7/m² 0.7/m² 0.7/m² 0.7/m² 0.7/m² 0.7/m²
8 Connect Hanger clip 0.7/m² 0.7/m² 0.7/m² 0.7/m² 0.7/m² 0.7/m²
10 Connect Angle trim 15/22, fixed at 300 mm centres as required as required as required as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M207) for Focus Frost Ds 1200x1200 mm
Size, mm
1200x1200
Focus Frost Ds 0.7/m²
1 Connect T24 Main runner HD 7101, installed at 1200 mm centres 0.9 m/m²
2 Connect Wall bracket T-profile 0524 1 for every row of Main runner
3 Connect Space bar 0520, installed at 1500 mm centres (max. distance from wall 300 mm) 0.7 m/m²
4 Connect Wall bracket Space bar 0525 1 for every row of Space bar
5 Connect Edge stiffener 0380 1.4/m²
6 Connect Stop clip 2 for every row of Main runner
7 Connect Split pin 0523, installed one per joint Main runner/Space bar 0.85/m²
8 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm) 0.7/m²
9 Connect Hanger clip 0.7/m²
10 Connect Angle trim 15/22, fixed at 300 mm centres as required
Quantity specification (excl. wastage)
Installation diagram (M208) for Focus Frost Ds, direct installation
Size, mm
600x600 1200x600 1600x600 2000x600 2400x600 1800x600
Focus Frost Ds 2.8/m² 1.4/m² 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Main runner HD 7101, installed at 600 mm centres 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m²
2 Connect Wall bracket T-profile 0524 1 for every row of Main runner 1 for every row of Main runner 1 for every row of Main runner 1 for every row of Main runner 1 for every row of Main runner 1 for every row of Main runner
3 Connect Cross tee 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner 2 for every row of Main runner
4 Connect Direct bracket 1012 1.1/m² 1.1/m² 1.1/m² 1.1/m² 1.1/m² 1.1/m²
6 Connect Angle trim 15/22, fixed at 300 mm centres as required as required as required as required as required as required

Sponsors of this page: database development, from and build