Ecophon Edge™ 500

Ecophon Edge 500 is a system used as free-hanging unit(s) in applications where the installation of a wall-to-wall ceiling is not possible or desired, but still good sound absorption is needed. Such applications are, for example, over a certain area in a larger room or in case of concrete cooling or ventilation systems that do not allow full coverage of the ceiling.
SYSTEM RANGE
Size, mm
2400
X
80 (Focus D standard sizes)

2400
X
80 (Focus DG standard sizes)

2400
X
80 (Focus E and Master E standard sizes)
Special fixing
Thickness 80 80 80
Inst. diagr. m163 m164 m165

The system consists of Connect Edge 500 Profile, Connect Edge 500 Corner and Connect connection details, which together form a well designed perimeter trim. The profile is manufactured from extruded aluminium, while the corners are cast zinc. Both have a white 500, structured powder coating to match the Akutex Frost surface of the tiles. The Edge profiles and Corners can be installed with Ecophon Focus Frost Ds and Focus Frost Dg systems in rectangles with modular dimensions. Ecophon Edge 500 has a design registration (Registered Community Design No 000293196-0001)

SOUND ABSORPTION: See Focus Frost Ds and Dg.

SOUND INSULATION: Not applicable.
SOUND PRIVACY: See Focus Frost Ds and Dg.

Ecophon Edge 500 Profile
Ecophon Edge 500 Corner
Connect Edge 500 in position for Focus Frost Ds installation
Connect Edge 500 in position for Focus Frost Dg installation
ACCESSIBILITY: The profiles are not demountable. The void can be accessed through the ceiling.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: Tiles: White 500, nearest NCS colour sample S 0500-N, 85 % light reflectance (of which more than 99% is diffuse reflection). Profile extrusion and corner are finished in white 500 structure.
INFLUENCE OF CLIMATE: The tiles can withstand a permanent ambient RH up to 95% at 30C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5. Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5. (applies for Focus/Master tiles).
ENVIRONMENTAL INFLUENCE: See respectively Focus Frost system. Metal components are fully recyclable.
FIRE SAFETY: See respectively Focus Frost system.
MECHANICAL PROPERTIES: Additional live load has to be secured to the soffit, but items with a weight of max. 1 kg, separated by min. 1m, can be attached to grid members.
INSTALLATION: Installed together with Focus Frost Ds according to installation diagram M210, Focus Frost Dg as per M211.
Installation Guides (pdf)
Size, mm
2400
X
80 (Focus D standard sizes)

2400
X
80 (Focus DG standard sizes)

2400
X
80 (Focus E and Master E standard sizes)
Installation Guide IG 163 IG 164 IG 165
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M163) for Ecophon Edge with Focus D
Size, mm
2400 x 80 (Focus D standard sizes)
Focus Edge as required
1 Connect Edge Profile as required
2 Connect Edge Corner as required
3 Connect Edge D2-profile as required
4 Connect L-coupling 1040 as required
5 Connect Wall bracket 0525 as required
6 Joint with Guide pins and Joint fixing bracket as required
7 Connect Main runner for adjustment and stabilisation of grid as required
8 Focus D tile and Connect D system as required
9 Wire suspension as required
Quantity specification (excl. wastage)
Installation diagram (M164) for Ecophon Edge with Focus DG
Size, mm
2400 x 80 (Focus DG standard sizes)
Focus Edge as required
1 Connect Edge Profile as required
2 Connect Edge Corner as required
3 Connect L-coupling 1040 as required
4 Joint with Guide pins and Joint fixing bracket as required
5 Focus DG tile and Connect grid as required
6 Wire suspension as required
7 Connect Main runner for adjustment and stabilisation of grid as required
Quantity specification (excl. wastage)
Installation diagram (M165) for Ecophon Edge with Focus E T24
Size, mm
2400 x 80 (Focus E and Master E standard sizes)
Focus Edge as required
1 Connect Edge Profile as required
2 Connect Edge Corner as required
3 Connect L-coupling 1040 as required
4 Joint with Guide pins and Joint fixing bracket as required
5 Focus E tile and Connect grid as required
6 Wire suspension as required