Ecophon Hygiene™ Inspection

To ensure a successful installation it is important to specify a full system, including inspection panels. Ecophon Inspection has been specially developed to suit Ecophon Hygiene ceilings. It is flush mounted in the ceiling to avoid pockets that could accumulate dirt and dust, and can withstand both manual washing and high-pressure hosing.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600

1200
X
1200
XL
1600
X
600
XL
1800
X
600
XL
2000
X
600
XL
2400
X
600
T24
T15        
Thickness 20 20 20 20 20 20 20
Inst. diagr. m01 m01 m01 m46
m16
m46
m16
m46
m16
m46
m16

The frame is made of powder-coated extruded aluminium, and is locked to the suspension grid by means of quick-release fasteners. The frame supports a 3.2 mm thick non-transparent acrylic panel and is sealed to the grid using a rubber gasket (EPDM). The weight is approximately 4 kg/m². Since the material will not support the growth of bacteria or mould and can be washed by advanced methods, it meets very strict hygiene demands

 To top





Product Focus A
O.d.s. mm 400 200 80 50
Absorption class   A A B
NRC 0.85     0.85
SAA 0.88     0.83

Hygiene Inspection Hatch.
Section of Hygiene Inspection Hatch A system with Connect C3.
Section of Hygiene Inspection Hatch C system with Connect C3.
Hygiene Inspection Hatch A system.
ACCESSABILITY: The tightly sealed, Hygiene Inspection is secured with quick-release fasteners for easy access. A 90-degree turn secures or releases the locker. Depending on size, 6 or 8 lockers are used to secure a unit. When demounted, the hanging panel is connected to the grid by two wires.
CLEANABILITY: Hygiene Inspection can either be cleaned in situ or can be demounted for cleaning on all sides. The product can withstand daily dusting and vacuum cleaning and weekly cleaning with a damp cloth or low-pressure/high-pressure washing.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m01, 1200x1200 50 160
m01, 1200x600 50 160
m01, 600x600 50 160
m16, 2400x600 0 -
m16, 2000x600 10 -
m16, 1800x600 20 -
m16, 1600x600 40 -
m46, 1600x600 50 160
m46, 1800x600 50 160
m46, 2000x600 50 160
m46, 2400x600 50 160
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M01) for Focus A
Size, mm
600x600 1200x600 1200x1200
Focus A 2.8/m² 1.4/m² 0.7/m²
1 Connect T24 or T15 Main runner, installed at 1200 mm centres 0.9 m/m² 0.9 m/m² 0.9 m/m²
2 Connect T24 or T15 Cross tee, L=1200 mm 1.7 m/m² 1.7 m/m² 0.9 m/m²
3 Connect T24 or T15 Cross tee, L=600 mm 0.9 m/m² - -
4 Connect Adjustable hanger, installed at 1200 mm centres (max distance from wall 600 mm) 0.7/m² 0.7/m² 0.7/m²
5 Connect Hanger clip 0.7/m² 0.7/m² 0.7/m²
6 For direct installation: Connect Direct bracket, installed at 1200 mm centres 0.7/m² 0.7/m² 0.7/m²
7 Connect Angle trim, fixed at 300 mm centres as required as required as required
8 Connect Shadow-line trim, fixed at 300 mm centres as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M16) for Focus A XL in corridors
Size, mm
1600x600 2000x600 2400x600 1800x600
Focus A 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Corridor profile, installed at 600 mm centres 1.05/m² 0.85/m² 0.7/m² 0.95/m²
2 Connect Angle trim, fixed at 200 mm centres as required as required as required as required
3 Connect Shadow-line trim, fixed at 200 mm centres as required as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M46) for Focus A XL
Size, mm
1600x600 2000x600 2400x600 1800x600
Focus A 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Main runner, installed at 600 mm centres 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m²
2 Connect T24 Cross tee, L=600 mm 0.65 m/m² 0.5 m/m² 0.45 m/m² 0.6 m/m²
3 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm) 1.1/m² 1.1/m² 1.1/m² 1.1/m²
4 Connect Hanger clip 1.1/m² 1.1/m² 1.1/m² 1.1/m²
5 Connect Angle trim, fixed at 300 mm centres as required as required as required as required
6 Connect Shadow-line trim, fixed at 300 mm centres as required as required as required as required