Ecophon Super G™

For ceilings in school corridors and other environments where there is some risk of mechanical impact. Ecophon Super G has an exposed grid system, with impact bracing bars or clips keeping the tiles in place. The tiles are demountable.
SYSTEM RANGE
Size, mm
600
X
600

1200
X
600
XL
1600
X
600
XL
1800
X
600
XL
2000
X
600
XL
2400
X
600
T24
Thickness 20/35 20/35 35 35 35 35
Inst. diagr. m199
m55
m199
m55
m59
m55
m59
m55
m59
m55
m59
m55

The systems consist of Ecophon Super G tiles and Ecophon Connect grid systems, with an approximate weight of 3-4 kg/m². The tiles are manufactured from high density glass wool. The visible surface has a strong glass fibre fabric and the back of the tile is covered with glass tissue. The edges are primedor natural. The grid is manufactured from galvanized steel.

SOUND ABSORPTION: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Not applicable.
SOUND PRIVACY: Not applicable.

αp Practical sound absorption coefficient
<em>α</em><sub>p</sub> Practical sound absorption coefficient
Frequency, Hz
Ecophon Super G 35mm, 200 mm o.d.s.
···· Ecophon Super G 35 mm, 50 mm o.d.s.
----Ecophon Super G 20 mm, 200 mm o.d.s.
o.d.s = overall depth of system

Product Super G A Super G A
O.d.s. mm 200 400 200 50
Absorption class A   A A
NRC 0.9 0.9 1 0.9
SAA 0.91 0.92 0.97 0.92

Super G tile
Section of Super G system with Connect T24
Super G system
Super G with Connect Impact bracing
ACCESSIBILITY: The tiles are demountable (one tile must be free of impact bracings). Minimum demounting depth according to installation diagrams.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 085. Nearest NCS colour sample: S 1002-Y. Light reflectance: 78%. Colours: See Ecophon Colour Range.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling and recommended by the Swedish Asthma and Allergy Association.
ENVIRONMENTAL INFLUENCE: Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
Country Standard Class
UK BS 476 Parts 6&7 Class 0
Europe EN 13501-1 A2-s1,d0
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: The Super G system has been tested according EN 13964 annex D (and DIN 18 032 part 3) and are classified as 2A (M55 and M59) and 3A (M199). For information regarding live load and requirements for load bearing capacity, see the table. Conditions: See Functional demands, Mechanical properties. Conditions: See Functional demands, Mechanical
Inst. diagr., Size (mm) Max live load (N) Min load bearing capacity (N)
m199, 1200x600 50 160
m199, 600x600 50 160
m55, 1200x600 40 160
m55, 1600x600 40 160
m55, 1800x600 40 160
m55, 2000x600 40 160
m55, 2400x600 40 160
m55, 600x600 40 160
m59, 2400x600 0 -
m59, 2000x600 10 -
m59, 1800x600 20 -
m59, 1600x600 40 -
INSTALLATION: Installed according to installation diagrams M55, M59 or M199, which include information regarding minimum overall depth of system.
Installation Guides (pdf)
Size, mm
600
X
600

1200
X
600
XL
1600
X
600
XL
1800
X
600
XL
2000
X
600
XL
2400
X
600
Installation Guide IG 55 IG 55 IG 55 IG 55 IG 55 IG 55
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
 To top
Quantity specification (excl. wastage)
Installation diagram (M199) for Super G (20mm)
Size, mm
600x600 1200x600
Super G A 2.8/m² 1.4/m²
1 Connect T24 Main runner, installed at 1200 mm centres 0.9 m/m² 0.9 m/m²
2 Connect T24 Cross tee L=1200 mm 1.7 m/m² 1.7 m/m²
3 Connect T24 Cross tee L=600 mm 0.9 m/m² m/m²
4 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm) 0.7/m² 0.7/m²
5 Connect Hanger clip (secured with screw) 0.7/m² 0.7/m²
6 Connect Hygiene clip 20 0172 11/m² 7/m²
7 Connect Channel trim 0532 as required as required
Quantity specification (excl. wastage)
Installation diagram (M55) for Super G and Super G XL, suspended installation
Size, mm
600x600 1200x600 1600x600 2000x600 2400x600 1800x600
Super G A 2.8/m² 1.4/m² 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Main runner, installed at 600 mm centres 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m² 1.7 m/m²
2 Connect T24 Cross tee, L=600 mm 1.7 m/m² 0.9 m/m² 0.65 m/m² 0.5 m/m² 0.45 m/m² 0.6 m/m²
3 Rigid hanger made of Connect Angle trim, max. L=1200 mm at 1200 mm centres 1.4/m² 1.4/m² 1.4/m² 1.4/m² 1.4/m² 1.4/m²
4 Connect Impact Bracing 3315 (Split pins included) 5.6/m² (2/tile) 4.2/m² (3/tile) 4.2/m² (4/tile) 4.2/m² (5/tile) 4.2/m² (6/tile) 4.6/m² (5/tile)
5 Connect Channel trim 0261, fixed at 300 mm centres as required as required as required as required as required as required
Quantity specification (excl. wastage)
Installation diagram (M59) for Super G XL in corridors
Size, mm
1600x600 2000x600 2400x600 1800x600
Super G A 1.05/m² 0.85/m² 0.7/m² 0.95/m²
1 Connect T24 Main runner HD 7101, installed at 600 mm centres 1.05 m/m² 0.85 m/m² 0.7 m/m² 0.95 m/m²
2 Connect Impact bracing 3315 (Split pins included) 4.2/m² (4/tile) 4.2/m² (5/tile) 4.2/m² (6/tile) 4.6/m² (5/tile)
3 Connect Channel trim 0261, fixed at 200 mm centres as required as required as required as required